Table 6-3: Clock Recovery Interface Signals
Interface Port Type Clock Domain Port Direction Description
control clock Clock N/A clk Input Control logic clock. This
clock runs the loop
controller and fPLL
reconfiguration related
blocks.
Note: Altera
recommends
that you set
about 60 MHz
to achieve
timing
closure. Set
the CLK_
PERIOD_NS
parameter
accordingly.
RX link clock Clock N/A rx_link_clk Input DisplayPort transceiver
link clock. This clock is a
divided version of the RX
main link clock. , or
divided by 4.
• Divided by 2 when
the sink core is
instantiated in 20-bit
mode (2 symbols per
clock)
• Divided by 4 when
the sink core is
instantiated in 40-bit
mode (4 symbols per
clock)
reset Reset
clk
areset Input Asynchronous reset. This
is an active-high signal.
UG-01131
2015.05.04
Clock Recovery Interface
6-7
DisplayPort IP Core Hardware Demonstration
Altera Corporation
Send Feedback