Bit Bit Name Function
5
SYM_LOCK1
0 = Symbol unlocked (lane 1)
1 = Symbol locked (lane 1)
4
SYM_LOCK0
0 = Symbol unlocked (lane 0)
1 = Symbol locked (lane 0)
3
CR_LOCK3
0 = Clock unlocked (lane 3)
1 = Clock locked (lane 3)
2
CR_LOCK2
0 = Clock unlocked (lane 2)
1 = Clock locked (lane 2)
1
CR_LOCK1
0 = Clock unlocked (lane 1)
1 = Clock locked (lane 1)
0
CR_LOCK0
0 = Clock unlocked (lane 0)
1 = Clock locked (lane 0)
DPRX_BER_CONTROL
Address: 0×0002
Direction: CRW
Reset: 0×00000000
Note:
When PHY_SINK_TEST_LANE_EN equals 1, CR_LOCK and SYM_LOCK bits (register DPRX_RX_STATUS)
are forced to 1 for lanes that are not being tested.
Table 10-6: DPRX_BER_CONTROL Bits
Bit Bit Name Function
31:28 Unused
27 RSTI3
Writing this bit at 1 resets lane 3 bit-error counter in
register DPRX_BER_CNTI1. Always reads as ‘0’.
26 RSTI2
Writing this bit at 1 resets lane 2 bit-error counter in
register DPRX_BER_CNTI1. Always reads as ‘0’.
25 RSTI1
Writing this bit at 1 resets lane 1 bit-error counter in
register DPRX_BER_CNTI0. Always reads as ‘0’.
24 RSTI0
Writing this bit at 1 resets lane 0 bit-error counter in
register DPRX_BER_CNTI0. Always reads as ‘0’.