Parameters
Table 15-1: Custom Instruction Slave BFM Parameter Settings
DescriptionLegal ValuesDefault
Value
Option
General
Specifies the number of operands to use.
• 0: no operands are used.
• 1: use dataa port only.
• 2: use dataa and datab ports.
0,1,22Number of Operands
to Use
Specifies the fixed length for multi-cycle mode.N/A2Fixed Length for Multi-
cycle Mode
Port Enables
When On, the interface includes a result pin.On/OffOnUse Result Port
When On, the interface can include a start pin, a done
pin, both pins, or neither pins. The result returns in
any of the following conditions:
• With a start signal—Result returns together with
an instruction.
• Without a start signal—Result returns with
instruction on the bus at every clock cycle.
• With a done signal—Result returns at any time.
• Without a done signal—Result returns at a fixed
cycle.
On/OffOffUse Multi-cycle Mode
When On, the interface includes a start pin.On/OffOn/Using start port
When On, the interface includes a done pin.On/OffOn/Using done port
When On, the interface includes a n pin.On/OffOffUse Extended Port
Specifies the width of the extended n port.N/A1Extended Port Width
When On, the interface includes the readra and a pins.On/OffOffUse Internal Register a
When On, the interface includes the readrb and b pins.On/OffOffUse Internal Register b
When On, the interface includes the readrc and c pins.On/OffOffUse Internal Register c
Miscellaneous Properties
For VHDL BFMs only. Use this option to assign a
unique number to each BFM in the testbench design.
0–10230VHDL BFM ID