Altera Avalon Verification IP Suite Manuale Utente Pagina 161

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 224
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 160
Parameters
The Tri-State Conduit BFM supports signals that interface to multiple external memory devices.
Table 12-1: Tri-State Conduit BFM Parameter Settings
DescriptionLegal ValuesDefault ValueOption
Specifies the role name of each port.Any stringN/ARole
Specifies the port width.110241Width
Specifies an input port.0 or 11USE_INPUT
Specifies an output port.0 or 11USE_OUTPUT
Specifies an output enable port.0 or 11USE_OUTPUTENABLE
Specifies the maximum transactions of
data while request and grant signals are
asserted. The value is constraint by the
number of roles.
N/A1024MAX_MULTIPLE_
TRANSACTION
Related Information
Avalon Interface Specifications
Avalon Tri-State Conduit Components User Guide
Tri-State Conduit BFM API
event_all_transactions_complete()
event_all_transactions_complete()Prototype:
Verilog HDL: N.A.
VHDL: None
Arguments:
voidReturns:
Notifies the testbench that all commands have completed.Description:
VHDLLanguage support:
Tri-State Conduit BFM
Altera Corporation
Send Feedback
Parameters
12-2
Vedere la pagina 160
1 2 ... 156 157 158 159 160 161 162 163 164 165 166 ... 223 224

Commenti su questo manuale

Nessun commento