Chapter 3: Functional Description 3–55
Signals
February 2013 Altera Corporation Serial Digital Interface (SDI) MegaCore Function
User Guide
PLL_SCANCLK
(7)
,
(8)
,
(9)
Input
Drives the
scanclk
signal on the transceiver PLL to be
reconfigured.
PLL_SCANCLKENA
(7)
,
(8)
,
(9)
Input
Acts as a clock enable for the
scanclk
signal on the transceiver
PLL to be reconfigured.
PLL_SCANDATA
(7)
,
(8)
,
(9)
Input
Drives the
scandata
signal on the transceiver PLL to be
reconfigured. This signal holds the scan data input to the
transceiver PLL for the dynamically reconfigurable bits.
PLL_SCANDONE
(7)
,
(8)
,
(9)
Output Determines when the transceiver PLL is reconfigured.
PLL_SCANDATAOUT
(7)
,
(8)
,
(9)
Output
This signal holds the transceiver PLL scan data output from the
dynamically reconfigurable bits.
Notes to Table 3–19:
(1) These signals must be connected directly to a reconfiguration megafunction.
(2) The transceivers are available for Arria GX, Arria II GX, Arria V, Cyclone IV GX, Cyclone V, Hardcopy IV GX, Stratix II GX, Stratix IV, and Stratix V
devices only.
(3) SDI transmitters do not require the use of transceiver dynamic reconfiguration but to enable the cores to merge into a transceiver quad that has
transceiver dynamic reconfiguration enabled, you must connect these ports correctly.
(4) In the Quartus II software version 8.1 and later, the Stratix IV transceivers requires receiver buffer calibration through an
ALTGX_RECONFIG
(transceiver dynamic reconfiguration) controller. The additional RECONFIG port bits are used for receiver buffer calibration. You must connect
these ports to the
ALTGX_RECONFIG
controller externally. For further information on the receiver buffer calibration, refer to the Stratix IV
Dynamic Reconfiguration chapter in volume 2 of the Stratix IV Device Handbook. If you are using the Quartus II software version 10.1, make
sure to upgrade the SDI MegaCore function to version 10.1 as well.
(5) N represents the number of channels instantiated.
(6) The
SDI_GXB_POWERDOWN
signal of all the instances that are to be combined in a single transceiver block must be connected to a single point
(same input or same logic). Any difference in the driving logic prevents the instances from being combined in a single transceiver block.
(7) This signal must be connected directly to the ALTPLL_RECONFIG megafunction, and only exposed to the top level when you select the Use PLL
reconfiguration for transceiver dynamic reconfiguration option in the SDI parameter editor.
(8) The transceivers are available for Cyclone IV GX devices only.
(9) You require
rx_std
and
sdi_start_reconfig
signals for PLL reconfiguration.
Table 3–19. Transceiver Dynamic Reconfiguration Signals (Part 2 of 2)
Signal Direction Description