Parameter Name Type Requi
red
Description
MUTIPLIER1_DIRECTION String No Specifies whether the second
multiplier adds or subtracts its
value from the sum. Values are
ADD and SUB. If the addnsub1 port
is used, this parameter is ignored.
If omitted, the default value is
ADD.
MUTIPLIER3_DIRECTION String No Specifies whether the fourth and
all subsequent odd-numbered
multipliers add or subtract their
results from the total. Values are
ADD and SUB. If the addnsub3 port
is used, this parameter is ignored.
If omitted, the default value is
ADD.
ACCUM_DIRECTION String No Specifies whether to use the
accumulator and whether the
accumulator adds or subtracts its
value from the sum. Values are
ADD and SUB. If omitted, the
default value is ADD.
OUTPUT_REGISTER String No Specifies the clock signal for the
second adder register. Values are
UNREGISTERED, CLOCK0,
CLOCK1, CLOCK2, and CLOCK3. If
omitted, the default value is
CLOCK0.
OUTPUT_ACLR String No Specifies the asynchronous clear
signal for the second adder
register. Values are NONE, ACLR0,
ACLR1, ACLR2, and ACLR3. If
omitted, the default value is
ACLR3.
PORT_SIGN[] String No Parameter [A,B]. Specifies the
corresponding sign[] input port
usage. Values are PORT_USED,
PORT_UNUSED, and PORT_
CONNECTIVITY. If omitted, the
default value is PORT_
CONNECTIVITY.
CHAINOUT_ROUND_TYPE String No Specifies the rounding mode at
the chainout stage. Values are
BIASED and UNBIASED. A value of
BIASED specifies round-to-
nearest-integer. A value of
UNBIASED specifies round-to-
nearest-even.
UG-01063
2014.12.19
ALTMULT_ADD Parameters
9-23
ALTMULT_ADD (Multiply-Adder)
Altera Corporation
Send Feedback
Commenti su questo manuale