Altera Integer Arithmetic IP Manuale Utente Pagina 105

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 157
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 104
Pre-adder
With pre-adder, additions or subtractions are done prior to feeding the multiplier.
There are five pre-adder modes:
Simple mode
Coefficient mode
Input mode
Square mode
Constant mode
Note: When pre-adder is used (pre-adder coefficient/input/square mode), all data inputs to the multiplier
must have the same clock setting.
Pre-adder Simple Mode
In this mode, both operands derive from the input ports and pre-adder is not used or bypassed. This is the
default mode.
Figure 9-2: Pre-adder Simple Mode
a0
b0
Mult0
result
Pre-adder Coefficient Mode
In this mode, one multiplier operand derives from the pre-adder, and the other operand derives from the
internal coefficient storage. The coefficient storage allows up to 8 preset constants. The coefficient
selection signals are coefsel[0..3].
The following settings are applied in this mode:
The width of the dataa[] input (WIDTH_A) must be less than or equals to 25 bits
The width of the datab[] input (WIDTH_B) must be less than or equals to 25 bits
The width of the coefficient input must be less than or equals to 27 bits
This mode is expressed in the following equation.
The following shows the pre-adder coefficient mode of a multiplier.
9-4
Pre-adder
UG-01063
2014.12.19
Altera Corporation
ALTMULT_ADD (Multiply-Adder)
Send Feedback
Vedere la pagina 104