Altera DDR SDRAM High-Performance Controllers and ALTMEMP Manuale Utente Pagina 121

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 140
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 120
Chapter 6: Functional Description—High-Performance Controller II 6–27
Register Maps
June 2011 Altera Corporation External Memory Interface Handbook Volume 3
Section I. DDR and DDR2 SDRAM Controllers with ALTMEMPHY IP User Guide
0x130
0 ENABLE_ECC 1 Read write
When this bit equals 1, it enables the
generation and checking of ECC. This bit is
only active if ECC was enabled during IP
parameterization.
1 ENABLE_AUTO_CORR Read write
When this bit equals 1, it enables
auto-correction when a single-bit error is
detected.
2 GEN_SBE 0 Read write
When this bit equals 1, it enables the
deliberate insertion of single-bit errors, bit 0,
in the data written to memory. This bit is
used only for testing purposes.
3 GEN_DBE 0 Read write
When this bit equals 1, it enables the
deliberate insertion of double-bit errors, bits
0 and 1, in the data written to memory. This
bit is used only for testing purposes.
4 ENABLE_INTR 1 Read write
When this bit equals 1, it enables the
interrupt output.
5 MASK_SBE_INTR 0 Read write
When this bit equals 1, it masks the
single-bit error interrupt.
6 MASK_DBE_INTR 0 Read write
When this bit equals 1, it masks the
double-bit error interrupt
7 CLEAR 0 Read write
When this bit equals 1, writing to this
self-clearing bit clears the interrupt signal,
and the error status and error address
registers.
8 MASK_CORDROP_INTR 0 Read write
When this bit equals 1, the dropped
autocorrection error interrupt is dropped.
9 Reserved. 0 Reserved for future use.
0x131
0 SBE_ERROR 0 Read only Set to 1 when any single-bit errors occur.
1 DBE_ERROR 0 Read only Set to 1 when any double-bit errors occur.
2 CORDROP_ERROR 0 Read only
Value is set to 1 when any
controller-scheduled autoconnections are
dropped.
7:3 Reserved. 0 Reserved for future use.
15:8 SBE_COUNT 0 Read only
Reports the number of single-bit errors that
have occurred since the status register
counters were last cleared.
23:16 DBE_COUNT 0 Read only
Reports the number of double-bit errors that
have occurred since the status register
counters were last cleared.
31:24 CORDROP_COUNT. 0 Read only
Reports the number of controller-scheduled
autocorrections dropped since the status
register counters were last cleared.
0x132 31:0 ERR_ADDR 0 Read only
The address of the most recent ECC error.
This address is a memory burst-aligned local
address.
Table 6–15. Controller Register Map (Part 4 of 5)
Address Bit Name Default Access Description
Vedere la pagina 120