Altera RapidIO II MegaCore Function Manuale Utente Pagina 145

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 218
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 144
Chapter 6: Software Interface 6–7
Physical Layer Registers
August 2014 Altera Corporation RapidIO II MegaCore Function
User Guide
The LP-Serial Lane Extended Features block for up to four lanes, including three
implementation-specific registers per lane.
The LP-Serial Lane Extended Features block implementation-specific registers
support software-driven control of transmitter pre-emphasis for both the local and
remote ends of the RapidIO link.
Table 65 shows the memory map for the RapidIO II IP core Physical layer.
Table 66 through Table 6–21 describe the registers for the Physical layer of the
RapidIO II IP core. The offset values within each of the two Extended Feature spaces
LP-Serial and LP-Serial Lane are defined by the RapidIO standard.
Table 6–5. Physical Layer Register Map
Address Name
Extended Features Space: LP-Serial
0x100 LP-Serial Register Block Header
0x104–0x11C Reserved
0x120 Port Link Time-out Control CSR
0x124 Port Response Time-out Control CSR
0x13C Port General Control CSR
0x140 Port 0 Link Maintenance Request CSR
0x144 Port 0 Link Maintenance Response CSR
0x148 Port 0 Local AckID CSR
0x14C–0x50 Reserved
0x154 Port 0 Control 2 CSR
0x158 Port 0 Error and Status CSR
0x15C Port 0 Control CSR
Extended Features Space: LP-Serial Lane
0x200 LP-Serial Lane Register Block Header
0x210 Lane 0 Status 0 (Local)
0x214 Lane 0 Status 1 (Far-End)
0x218 Lane 0 Status 2 (Interrupt Enable)
0x21C Lane 0 Status 3 (Received CS Field Commands)
0x220 Lane 0 Status 4 (Outgoing CS Field)
0x230–0x280 Lane 1–3 Status
Table 6–6. LP-Serial Register Block Header—0x100
Field Bits Access Function Default
EF_PTR
[31:16] RO
Hard-wired pointer to the next block in the data structure. The value in
this field is the address of the LP-Serial Lane Extended Features block,
which is 0x200.
16'h0200
EF_ID
[15:0] RO Hard-wired extended features ID. 16'h0002