4–4 Chapter 4: Functional Description
Clocking and Reset Structure
RapidIO MegaCore Function August 2014 Altera Corporation
User Guide
1 You must drive the Avalon system clock from a clock source that is running reliably
when the RapidIO IP core comes out of reset.
Reference Clock
The reference clock signal drives the transceiver and the Physical layer. By default,
this clock is called
clk
in the generated IP core. Qsys allows you to export the
clk
signal with a name of your choice.
The reference clock,
clk
, is the incoming reference clock for the transceiver’s PLL. The
frequency of the input clock must match the value you specify for the Reference clock
frequency parameter. The transceiver PLL converts the reference clock frequency to
the internal clock speed that supports the RapidIO IP core baud rate.
The RapidIO parameter editor lets you select one of the supported frequencies. The
selection allows you to use an existing clock in your system as the reference clock for
the RapidIO IP core.
1 You must drive the external transceiver TX PLL
pll_refclk0
input clock from the
same source from which you drive the RapidIO IP core
clk
input clock.
Figure 4–1 shows how the transceiver uses the reference clock in non-Arria 10
variations. In Arria 10 variations,
clk
is the reference clock only for the RX PLL. In
these variations, the reference clock for the TX PLL is an input signal to the TX PLL IP
core that you connect to the RapidIO IP core. For Arria 10 variations, refer to the Arria
10 Transceiver PHY User Guide.
The PLL generates the high-speed transmit clock and the input clocks to the receiver
high-speed deserializer clock and recovery unit (CRU). The CRU generates the
recovered clock (
rxclk
) that drives the receiver logic.
Figure 4–1. Reference Clock in a non-Arria 10 RapidIO IP Core
(1)
Note to Figure 4–1:
(1) This figure does not show the Custom PHY IP core clock
phy_mgmt_clk
.
Avalon system clock
rd
td
Transceiver
RapidIO MegaCore function
Serial Interfaces
4
4
PLL
Receiver
txgxbclk
TX data
rxgxbclk
RX data
Reference
Clock
txclk
rxclk
PLL
CRU
Transmitter