Altera JNEye Manuale Utente Pagina 75

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 194
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 74
Figure 2-51: JNEye Channel Viewer Example
Refer to the Tutorial: PCI Express 8GT chapter for step-by-step channel setup instructions.
Automatic S-parameter Configuration Check (ASCC)
JNEye uses a proprietary Automatic S-parameter Configuration Checker (ASCC) to help you set and
connect the S-parameter in the channel chain. With ASCC, JNEye inspects the S-parameter model and
determines the port number and port configuration. ASCC also selects the middle lane as the victim
channel (insertion loss channel) and sets the Lane and Aggressor pull-down menus for user configuration.
Channel configuration information is saved individually for each channel. Therefore, S-parameters with
different port numbers and/or port configurations can be mixed and cascaded in JNEye.
Related Information
Tutorial: PCI Express 8GT on page 3-1
Crosstalk Aggressor Transmitter Setting on page 2-73
UG-1146
2015.05.04
Channel Setting
2-69
Functional Description
Altera Corporation
Send Feedback
Vedere la pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 193 194

Commenti su questo manuale

Nessun commento