Altera GPIO Manuale Utente Pagina 13

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 22
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 12
Data Interface Signals and Corresponding Clocks
The following table shows the data interface signals and the corresponding clocks.
Table 3: Data Interface Signals and Corresponding Clocks
Signal Name Configuration Clock
din
Register Mode: Simple
Register/DDIO
ck
Half-rate: not used
Separate Clocks: Off
Register Mode: DDIO
ck_hrHalf rate: used
Separate Clocks: off
Register Mode: Simple
Register/DDIO
ck_in
Half rate: not used
Separate Clocks: on
Register Mode: DDIO
ck_hr_inHalf rate: used
Separate Clocks: on
dout/oe
Register Mode: Simple
Register/DDIO
ck
Half rate: not used
Separate Clocks: off
Register Mode: DDIO
ck_hrHalf rate: used
Separate Clocks: off
Register Mode: Simple
Register/DDIO
ck_out
Half rate: not used
Separate Clocks: on
Register Mode: DDIO
ck_hr_outHalf rate: used
Separate Clocks: on
ug-altera_gpio
2014.08.18
Data Interface Signals and Corresponding Clocks
13
Altera GPIO IP Core User Guide
Altera Corporation
Send Feedback
Vedere la pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 21 22

Commenti su questo manuale

Nessun commento