Altera Quartus II Settings File Manuale Utente Pagina 126

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 134
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 125
MAX_LABS
Allows you to specify the maximum number of LABs that Analysis & Synthesis should try to utilize for a
device. This option overrides the usual method of using the maximum number of LABs the current device
supports, when the value is non-negative and is less than the maximum number of LABs available on the
current device.
Type
Integer
Device Support
This setting can be used in projects targeting any Altera device family.
Notes
This assignment is included in the Analysis & Synthesis report.
This assignment supports synthesis wildcards.
Syntax
set_global_assignment -name MAX_LABS <value>
set_instance_assignment -name MAX_LABS -to <to> -entity <entity name>
<value>
Default Value
-1 (Unlimited)
Example
set_global_assignment -name max_labs 100
126
MAX_LABS
MNL-Q21005
2015.05.04
Altera Corporation
Quartus Settings File Reference Manual
Send Feedback