Chapter 2: Board Components and Interfaces 2–5
Configuration, Status, and Setup Elements
© November 2008 Altera Corporation Data Conversion HSMC Reference Manual
Mode Select Jumper (J11)
The mode select jumper is used to put the D/A converter in either dual bus or
interleaved mode. It is selectable through J11 (channel A and channel B). Table 25
lists the jumper settings for mode select options.
Gain Select Jumper (J10)
The gain setting select jumper is used to set gain of the D/A converter’s channels. It is
selectable through J10 (channel A and channel B). Table 2–6 lists the jumper settings
for gain settings options.
Sleep Select Jumper (J13)
The sleep select jumper is used to put the D/A converter in power down mode. It is
selectable through J13 (channel A and channel B). Table 2–7 lists the jumper settings
for sleep select options. The D/A converter when not in use should be put in sleep
mode.
Table 2–5. Mode Select Jumper (J11) Settings for DAC5672 D/A Converter
Jumper Settings (J11) Description
Jumper ON Interleaved mode
Jumper OFF Dual bus mode
Table 2–6. Gain Select Jumper (J10) Settings for DAC5672 D/A Converter
Jumper Settings
(J10) Description
Jumper ON Sets gain of channel A through RSET on BiasJ_A pin, and of channel B
through RSET on BiasJ_B pin.
Jumper OFF Gain of channels A and B is set through RSET on BiasJ_A pin only and
RSET on BiasJ_B pin is ignored.
Table 2–7. Sleep Select Jumper (J13) Settings for DAC5672 D/A Converter
Jumper Settings
(J13) Description
Jumper ON Puts D/A converter in power down mode
Jumper OFF D/A converter in normal state