Chapter 6: Board Test System 6–19
Using the Board Test System
July 2012 Altera Corporation Arria V GX FPGA Development Kit
User Guide
The SDI/Bullseye Tab
The SDI/Bullseye tab (Figure 6–8) allows you perform loopback tests on the Bull’s
Eye and SDI ports.
The following sections describe the controls on the SDI/Bullseye tab.
Status
The Status control displays the following status information during the loopback test:
PLL lock—Shows the PLL locked or unlocked state.
Channel lock—Shows the channel locked or unlocked state. When locked, all
lanes are word aligned and channel bonded.
Pattern sync—Shows the pattern synced or not synced state. The pattern is
considered synced when the start of the data sequence is detected.
Figure 6–8. The SDI/Bullseye Tab